Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Attic ventilation requirements texas.
Mechanical ventilation shall be provided by a method of supply air and return or exhaust air except that mechanical ventilation air requirements for group r 2 r 3 and r 4 occupancies three stories and less in height above grade plane shall be provided by an exhaust system supply system or combination thereof.
An opening not less than 20 inches by 30 inches shall be provided to any attic area having a clear height of over 30 inches.
Calculations indicate that on a july day in texas a ventilation rate of one air change per minute for a typical attic using 95 degree f air will lower the peak attic temperature to about 101 degrees f.
Tips for assessing your needs.
Ventilation of attic spaces is required by most building codes as well as by roofing material manufacturers and the national roofing contractors association nrca.
The nominal size of wire used with a 100 amp service shall be no.
Most building codes require a ratio of 1 150 ventilation space to attic floor space.
Of vent for every 300 sq.
Once they are in place you can then place the batts or blankets or blow insulation right out to the very edge of the attic floor.
Residents of southern and central texas should insulate their attics to at least r 30 or about 9 5 inches of conventional fiberglass batt insulation.
In order to facilitate this exchange of warm and cool air the general rule of thumb suggests installing at least 1 sq.
Building codes vary.
For large volume attics such as where roof slopes are greater than 8 12 designers also should consider increasing.
For a 200 amp service the nominal size shall be no.
Providing half air change per minute will lower the temperature to about 106 degrees f.
Regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation ratio measured at the attic floor level ceiling.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
The minimum service entrance shall be 100 amperes with a 3 wire 120 240 volt single phase service with a grounded neutral.
You can also contact your local municipality to check on building code in your area.
A 30 inch minimum clear headroom in the attic space shall be provided at or above the access opening.